
Fall refers to falling to a lower position or floor than an individual's intention during daily life [1] and falls due to loss of balance can cause serious complications such as trauma and fractures [2]. In particular, aging causes functional loss and degeneration of all organs and tissues. Also, it increases instability in everyday life [3]. According to the Korea Ministry of Health and Welfare survey of senior citizens aged 65 and older, the rate of falling is about 15.9% per year, and the rate of hospitalization is about 64.9% [4].
Balance is the ability to maintain the center of gravity (COG) of the body in the basal plane [5], and is an essential component of functional activity during daily life [2]. The body requires delicate interactions of the motor and sensory systems to maintain balance [6], however, it is reduced by aging-induced muscle strength, impaired proprioceptive sense, vestibular and visual impairment, and delayed response time, as a result, increases the risk of falls [7, 8].
Currently, various examination methods are being tried for balance evaluations. Romberg test can be applied conveniently without any space constraints and is still widely used today as an easy method. Although such a highly utilized evaluation method, it has the disadvantage that quantitative measurement is difficult [9]. Clinics use a lot of equipment to measure center of pressure (COP) in force plate and insole, but it is expensive and requires a large space and expertise [10, 11]. On the other hand, smartphones have less space-time constraints, and frequency collection using acceleration sensors shows high potential for static balance evaluation [12].
Recently, in preparation for the prolonged COVID-19 pandemic, the government has made efforts to make non-face-to-face medical care a regular medical service [13], which has highlighted the importance of tele-rehabilitation. However, there are challenges for clinicians in understanding and technology to evaluate and manage patients remotely [14].
Smartphones are easily accessible and have high potential in tele-rehabilitation for neurological patients, and are actually studying various rehabilitation possibilities using smartphones [15-17]. An inertial measurement unit (IMU), which is key to various rehabilitation studies using smartphones, is a device that measures the speed, direction, gravity, and acceleration of moving objects, consisting of acceleration sensors, geomagnetic sensors, and gyroscope sensors [18]. Various studies have been conducted clinically to develop a smartphone-based balance assessment system by attaching acceleration sensors and gyroscope sensors to the body [17-20].
However, due to the lack of studies that evaluate the reliability of measuring postural sway through two sensors mounted on smartphones while verifying their validity against other balance equipment, it is somewhat difficult to utilize the two sensors in clinical setting.
Therefore, we would like to utilize acceleration sensors and gyroscope sensors to evaluate their balance abilities, verify their reliability and validity, and propose a new balance evaluation methods that can be conveniently used without space-time constraints.
52 healthy adults aged 20 to 50 in the K hospital in Seoul were selected as subjects based on their agreement. Five people who did not meet the pre-experimental criteria were excluded, and two were eliminated during the experiment. Thus, 45 subjects were finally selected. After collecting general features including gender, age, weight, and height. The pre-test was measured with the dominant foot kicking the ball through a ball kick [21] (Table 1). Exclusion criteria were those who had fallen in their daily lives, those who had nervous system, musculoskeletal system disease or damage, and those who had exercised excessively within the past week. This study was reviewed by the Institutional Review Board of Sahmyook University, Seoul. The serial number for the review is 2-1040781-A-N-012021015HR.
The participants of this study wore their smartphones as a belt around their waist (Sacrum 2) and performed the six static balance tests; Shoulder-width-stance with eye open (SWS-EO), Shoulder-width-stance with eye closed (SWS-EC), Feet-together-stance (FTS), Semi-tandem-stance (STS), Tandem-stance (TS), and One-leg stance (OLS) [20, 22] (Figure 1). In order to verify the concurrent validity, all posture measurements were made on the force plate, and simultaneously through an application that records the smartphone inertial sensors. They were repeated twice for 35 seconds. When tests were completed, results were repeated a day later (24 hours) with the same postures and methods in order to identify the test-retest reliability [19]. A Galaxy S20 (SM-G981N, Samsung, Korea) mounted with an inertial sensor (LSM6DSO MEMS, STMicroelectronics, Switzerland) was used to measure the static balance tests. The smartphone was set to horizontal mode and fixed with a belt to the subject's waist (Sacrum 2), and Sensor kinetics pro (Sensor kinetics pro ver.3,1.2, Innovations Inc., US) was run simultaneously with the start of the experiment to measure acceleration data and gyroscope data.
The acceleration data was based on the Z-axis movement as Accelerometer root mean scale anteroposterior (ARMS-AP) and the Y-axis movement as Accelerometer root mean scale mediolateral (ARMS-ML), and the values obtained through the square root of the Z-axis and Y-axis was normalized to the accelerometer root mean scale total (ARMS-Total).
Gyroscope data was the gyroscope root mean scale pitch (GRMS-Pitch) for the movement of the pitch and the gyroscope root mean scale roll (GRMS-Roll) for the movement of the roll, and the gyroscope root mean scale total (GRMS- Total).The data calculated by the gyroscope sensor was multiplied by 180÷π to the calculated data value to change the unit from rad/s to degree/s [20] (Figure 2).
The data of the force plate measured by the movement of COG was normalized to the following three data; Center of pressure velocity anteroposterior (COPV-AP), Center of pressure velocity mediolateral (COPV-ML), and Mean sway velocity (MSV) obtained through the square roots of the X-axis and Y-axis.
SPSS software (SPSS ver.20.0, IBM SPSS Statistics, USA) was used for all operations and statistics, and descriptive statistics were used for general characteristics. In order to confirm the reliability of the acceleration data and gyroscope data measured in the first and second trials, each data was analyzed as an intra-class correlation coefficient (ICC 3,1). Pearson's correlation analysis was used to verify the validity of the smartphone inertial sensor-based application. A significance level was set at a p-value of <0.05.
The reliability of the acceleration sensor showed a very high correlation (ICC>0.90) in all postures (p<0.001). The reliability of the gyroscope sensor showed a very high (ICC>0.90) or high correlation (ICC>0.75) in all postures (p<0.001), which can be shown as below (Table 2).
Most of tandem-stance and one-leg-stance showed a poor to fair correlation (0.3
Deterioration in the ability to maintain posture is the cause of falls, and restoration of balance becomes a key goal in the rehabilitation process. Thus, objective evaluation of balance is clinically an important indicator in tracking disease or performing therapeutic interventions [24]. Since the force plate measures the movement of the COP, it measures the velocity on the ground. As activities to increase body stability in both feet increase, the values proportionately increase. On the other hand, the smartphone inertial sensor measures the value of acceleration and angular velocity through the movement of COM from the body. As the body's activity increases, these values become larger [23] Therefore, two signals differ slightly in the movement position, so the relationship cannot be expressed as completely linear [19]. However, because both variables show body sway in proportion to the numerical value and the inertial measurement technologies have the potential to be a reliable alternative compared to the balance evaluation of the force plate [25], many studies have compared simultaneous validity through analysis between the two signals [19, 23, 26, 27]. Therefore, this study tried to verify that the acceleration sensor and gyroscope sensor mounted in smartphones have reliability and validity in measuring the static balance abilities.
First, it was found that both sensors have high reliability when measuring six static balance tests. The studies of Hou et al. [20] and Lee. D. H et al. [28] showed similar results to this study that both sensors have high reliability, and supports the results of this study. On the other hands, the reliability of this study was higher than the study of De Groote et al. [19], which reported that the smartphone acceleration sensor has moderate-high reliability. The reason is that this study used a smartphone equipped with an LSM6DSO sensor with improved accuracy than the LSM6DS3 sensor used in De Grootés research. In addition, the study was analyzed through the RMS values of the Z-axis and Y-axis data, respectively, however, in this study, the mechanical error was corrected by analyzing the total RMS obtained through the square of the two axes, and the reliability value could be increased. Therefore, it is believed that the smartphone acceleration sensor and gyroscope sensor can measure the static balance consistently and reliably.
Second, this study found that it has a higher validity when measuring balance abilities with the gyroscope sensor than with the acceleration sensor. It shows similar results to the studies of De Groote et al. [20] and Han Seul-gi et al. [29] that there was negligible correlation when performing balance tasks with low difficulty level, and that there was a fair or higher correlation when performing balance tasks with higher difficulty level. O'Sullivan et al. [30] reported that acceleration data can be measured in more difficult balance tasks, which supports this study. The reason is that, in the bipodal postures, only minute postural fluctuations occur in the ankle with a wide BOS, so it is not recorded as acceleration data measuring instantaneous postural fluctuations. However, in the tandem stance and one leg stance, the movements of the ML and AP axes appear as large fluctuations due to the narrowed left and right BOS, and are recorded in the acceleration sensor. On the other hand, the reason that the correlation of this study was lower than that of Ruopeng Sun et al. [25] is because the subjects of this study were healthy adults with superior balance ability than those with multiple sclerosis. Thus, it was judged that it was difficult to measure minute postural fluctuations in the easy postures with acceleration data representing strong body movements. A similar study by Koller et al. [31] reported that the acceleration sensor was unable to distinguish between mild multiple sclerosis patients and healthy adults in a low-difficulty static balance postures.
Also, most of the previous static balance measurements only studied the correlation between the acceleration sensor and the force plate [32-34]. However, in this study, the correlation between the gyroscope sensor and the force plate was compared, and it was confirmed that there was poor to fair correlations (0.3
There are several limitations in this study. First, this study fixed the smartphone to sacrum two. However, the result values can differ depending on the location of the smartphone attachment because the movements of the ankle, knee, and hip joint may appear as different balance strategies. Therefore, efforts are required to try to quantitatively measure balance tests in various body parts. Second, the sample in the study was homogeneous, consisting of healthy adults aged 20 to 50. In future studies, it will be necessary to conduct studies on various groups, such as patients with difficulty in balance and elderly people with high risk of falling. Third, the test interval was short, so the learning effect was likely to be involved. In future studies, it is necessary to verify the reliability in various aspects. Finally, it took a lot of time to organize a large amount of data because Sensor kinetics pro used to derive inertial data is not a system developed solely to measure balance. In future studies, it will be necessary to develop an application that can calculate data and implement it with an easy quantitative measurement methods.
General characteristics of participations (N=45)
Mean±SD | |
---|---|
Gender(M/F) | 22/23 |
Age (year) | 34.64±8.33 |
Heights (cm) | 167.42±7.73 |
Weight (kg) | 62.27±11.22 |
Dominant Foot (R/L) | 40/5 |
Reliability of smartphone inertial sensors (N=45)
Sensor | Postures | a ICC | b 95% CI |
---|---|---|---|
Acceleration | SWS-EO | 0.978** | 0.960-0.988 |
SWS-EC | 0.915** | 0.846-0.953 | |
FTS | 0.958** | 0.924-0.977 | |
STS | 0.962** | 0.931-0.979 | |
TS | 0.916** | 0.847-0.953 | |
OLS | 0.949** | 0.908-0.971 | |
Gyroscope | SWS-EO | 0.885** | 0.791-0.937 |
SWS-EC | 0.902** | 0.822-0.946 | |
FTS | 0.840** | 0.709-0.912 | |
STS | 0.786** | 0.610-0.882 | |
TS | 0.760** | 0.564-0.868 | |
OLS | 0.903** | 0.824-0.947 |
a Intra-class correlation coefficient (ICC 3,1).
b 95% Confidence Interval.
Validity of acceleration sensor and force plate (N=45)
Postures | ARMS/FP COPV | a PCC (p) | b 95% CI |
---|---|---|---|
SWS-EO | AP | 0.013 (0.937) | -0.347∼0.533 |
ML | 0.130 (0.419) | -0.341∼402 | |
Total/MSV | 0.157 (0.328) | -0.290~0.569 | |
SWS-EC | AP | 0.015 (0.549 | -0.160∼0.394 |
ML | 0.096 (0.548) | -0.160∼0.394 | |
Total/MSV | 0.104 (0.516) | -0.167∼0.431 | |
FTS | AP | -0.089 (0.604) | -0.261∼0.124 |
ML | 0.143 (0.371) | -0.057∼0.419 | |
Total/MSV | 0.004 (0.981 | -0.160∼0.204 | |
STS | AP | 0.028 (0.862) | -0.245∼0.337 |
ML | 0.102 (0.524) | -0.071∼0.464 | |
Total/MSV | 0.121 (0.452) | -0.092∼0.373 | |
TS | AP | 0.405 (0.009)** | -0.151∼0.719 |
ML | 0.289 (0.067) | -0.006∼0.564 | |
Total/MSV | 0.408 (0.008)** | -0.016∼0.681 | |
OLS | AP | 0.299 (0.057) | -0.101∼0.590 |
ML | 0.556 (0.000)** | 0.291∼0.749 | |
Total/MSV | 0.542 (0.000)** | 0.303∼0.725 |
a Pearson’s correlation coefficient.
b 95% Confidence Interval.
Validity of gyroscope sensor and force plate
Postures | GRMS/FP COPV | a PCC (p) | b 95% CI |
---|---|---|---|
SWS-EO | Pitch/AP | 0.470 (0.009)** | 0.068∼0.711 |
Roll/ML | 0.427 (0.019)* | 0.015∼0.683 | |
Total/MSV | 0.623 (0.000)** | 0.277∼0.811 | |
SWS-EC | Pitch/AP | 0.470 (0.009)** | 0.144∼0.734 |
Roll/ML | 0.560 (0.001)** | 0.255∼0.771 | |
Total/MSV | 0.661 (0.000)** | 0.385∼0.839 | |
FTS | Pitch/AP | 0.709 (0.000)** | 0.519∼0.842 |
Roll/ML | 0.413 (0.023)* | 0.049∼0.664 | |
Total/MSV | 0.684 (0.000)** | 0.466∼0.829 | |
STS | Pitch/AP | 0.645 (0.000)** | 0.385∼0.839 |
Roll/ML | 0.474 (0.008)** | 0.110∼0.791 | |
Total/MSV | 0.623 (0.000)** | 0.300∼0.849 | |
TS | Pitch/AP | 0.364 (0.019)* | 0.079∼0.629 |
Roll/ML | 0.636 (0.000)** | 0.381∼0.822 | |
Total/MSV | 0.450 (0.003)** | 0.074∼0.719 | |
OLS | Pitch/AP | 0.559 (0.001)** | 0.358∼0.740 |
Roll/ML | 0.663 (0.000)** | 0.443∼0.829 | |
Total/MSV | 0.640 (0.000)** | 0.440∼0.799 |
a Pearson’s correlation coefficient.
b 95% Confidence Interval.